Mark Beno, Deputy Director
BESSRC has one bending magnet beamline which is designed for general spectroscopic, diffraction and scattering experiments. The 12BM beamline has a first optics enclosure (FOE) and a single experimental station at approximately 50 m from the source. The FOE contains all the major beamline components. The 12BM beamline is window-less so that the beamline vacuum is directly connected to the ring vacuum, allowing the beamline to operate at energies as low as 2.5 keV. The first component inside the FOE is a differential pump which contains a mask limiting the beam to 2.5 mrad horizontal and a vertical aperture of 200 mrad. The beam size can be further restricted by independent horizontal and vertical white-beam slits which can be used to determine the vertical beam divergence and thus the energy resolution of the monochromator as well as the horizontal beam width which is incident on the monochromatorÕs first crystal. The last white-light component in the FOE is a water-cooled fixed exit double crystal monochromator. The beamline can be operated in two modes: either the unfocussed monochromatic beam can be used, or a double mirror system consisting of a flat mirror deflecting the monochromatic beam downward to a toroidal Rh coated glass mirror can focus the beam into the 12BM experimental station. The last component in the FOE is a white-light beam shutter/ stop. The shielded UHV beam transport ends with monochromatic slits which are located in a small shielded enclosure immediately in front of the 12BM experimental station. The large experimental station (6 m by 3 m) has an optical table (1.2 m x 1.8 m) for spectroscopic experiments and a Huber 6-circle vertical goniometer for diffraction and scattering investigations permanently installed.

Figure 1
Front view of the monochromator system. The vacuum chamber is 24 inches in diameter and has 27 inch OD wire sealed UHV flanges. Separate ion pumps are used for each side of the chamber so that a differential pressure of 10-3 torr can be obtained. The chamber is mounted on a precision kinematic table.
The BESSRC 12BM monochromator is a double crystal, fixed exit monochromator with a constant 35 mm offset designed for UHV operation[1], thereby allowing windowless operation of the beamline. A mechanical linkage and a stepper-motor driven slide are used to correctly position the second crystal and maintain a constant offset. The crystals are mounted on a turntable with the first crystal at the center of rotation. The main drive for the rotary motion is provided by a vacuum compatible Huber 430 goniometer which is isolated from the main vacuum chamber. Rotary motion of the primary monochromator stage is accomplished by using two adjacent vacuum chambers linked only by the small annular opening around a hollow stainless steel shaft which connects the Huber goniometer to the turntable on which the crystals are mounted. This design allows high vacuum operation of the monochromator since it is possible to maintain 10-9 Torr on the monochromator side while maintaining only 10-7 Torr in the goniometer vacuum chamber. The design consists of two matching perfect crystals mechanically linked by way of two slides mounted orthogonal to each other (a Cowan- Golovchenko linkage[2,3]). The vertical slide for the second crystal mount is driven by a roller at the apex while an in-vacuum stepper motor drives the horizontal slide. In-vacuum stepper motors driven micrometers are used for the c and q rotations of a kinematic mount on which the second crystal is mounted. An electrostrictive translator mounted in opposition to the theta micrometer provides nearly backlash free fine adjustment of the second crystal for feedback. Large changes in energy tuning are achieved by using the rotary drive mechanism in conjunction with the translation of the second crystal. To scan energy, for example for a spectroscopy experiment, the second crystal drive mechanism is held fixed and the beam diffracted from the first crystal is allowed to walk on the surface of the second crystal. Since the vertical slide of the Cowan- Golovchenko linkage is driven by a mechanical linkage this mode of operation maintains the fixed-exit operation of the monochromator. Water flow cools a copper block onto which the first crystal is clamped. A Ga-In eutectic mixture provides enhanced conduction between the Si111 first crystal and the cooled copper plate. The water lines are double shielded so that there are no water to ring vacuum joints in the UHV chamber. Because of the high critical energy of the APS bending magnet beamlines, 19 keV, Compton scattering heats the second crystal. To eliminate long term thermal drifts from this heating the second crystal is cooled by Cu braid connected to the monochromator chamber and a radiator plate designed to increase radiative cooling. Front and side views of the monochromator are given in Figures 1 and 2. The monochromator uses Si 111 crystals and is limited to rotation angles from 3¡ to 55¡ providing energies from 2.4 to 30 keV. By using the Si 333 (third harmonic) reflection energies of 30 to 90 keV are accessible.

Figure 2
Drawing showing the side view of the BESSRC bending magnet monochromator. The vertical slide of the right angle linkage connecting the two perfect Si 111 crystals is driven by a roller riding on the invar bar which spans the monochromator chamber while the horizontal slide is driven by a rack and pinion gear. Only manual adjustments are used for the initial alignment of the first crystal, but the second crystal can be driven in both q and c by in-vacuum stepper motors.
The monochromatic double mirror system is designed to permit
use of the focussing mirror in the 12BM experimental station without changing
the angle of the ~25 m long shielded UHV beam transport tubes or translation of
the monochromatic slits. The use
of the double mirror system allows the rapid switching of the beamline from
focused to unfocussed mode by raising the first mirror out of the beam. The first downward deflecting flat
mirror is a Zerodur flat 40 cm long, 5 cm wide and 25 mm thick coated with a 20
mm wide Pd film. The second upward
deflecting toroidal mirror is Rh coated silica and is 60 cm long, 10 cm wide
and 4 cm thick with a saggital radius of 8 cm. The toroidal mirror is at approximately 29 m from the source
and is at the 1 to 1 position so the fixed saggital radius determines the
incident angle of 2.7 mrad. At
this angle the mirror cutoff is approximately the Rh K edge energy of 23 keV. Both mirrors are mounted on kinematic
tables. Only the toroidal mirror
has translations to adjust its angle with respect to the incident beam. A 4-point bender adjusts the meridional
radius of the toroidal mirror. The
mirrors are capable of providing a focus of approximately 0.5 x 0.5 mm with a
photon flux of 8 x 1011 photons/mm2sec at 10 keV.
The 12BM-B experimental station is located at 55 m from the source point. The station is equipped with a kinematic optical table for spectroscopy and a Huber 6-circle also mounted on a kinematic table. The optical table can be translated to give 400 mm of clearance for the beam and has the capacity (>200kg) to be used for large cryostats or magnets. Ion chambers, single and multi-element solid state (Ge) detectors and photomultiplyer detectors are available. Ancillary equipment available includes a DISPLEX system, turbo pump, and He flow Cryostat.
Diffraction or scattering experiments in the 12BM-B station on the Huber 6-circle goniometer or spectroscopy experiments on the stations optical table may be controlled with Windows based software [4], a Macintosh based IGOR interface [ 5] or using SPEC [6] on a LINUX system. For the first two operating systems EPICS is used to control the beamline components, for SPEC a BIT3 card in the 12BM-B stations VME crate controls all the stations motors while the monochromator and other beamline components are controlled with an EPICS interface.
1. M. Ramanathan, M. A. Beno, G. S. Knapp, G. Jennings, P. L. Cowan, and P. A. Montano, Rev. Sci. Instr., , 66 (1995) 2191.
2. J. A. Golovchenko, R. A. Levesque, and P. L. Cowan, Rev. Sci. Instr. 51 (1981) 509.
3. P. L. Cowan, J. B. Hastings, T. Jach and J. P. Kirkland, Nucl. Instr. and Meth. 208 (1983) 349.
4. M. Engbretson, Rapid Application Development (RAD) Software for Synchrotron Beamline Control, in preparation.
5. G. Jennings, Synchrotron Beamline and Instrument Control with IGOR, in preparation.
6. Certified Scientific Software, Cambridge, MA.